{"id":412,"date":"2023-08-21T10:22:59","date_gmt":"2023-08-21T14:22:59","guid":{"rendered":"https:\/\/sites.miamioh.edu\/instrumentationlab\/?page_id=412"},"modified":"2023-08-21T10:36:03","modified_gmt":"2023-08-21T14:36:03","slug":"ta-current-and-temperature-control-system","status":"publish","type":"page","link":"https:\/\/sites.miamioh.edu\/instrumentationlab\/ta-current-and-temperature-control-system\/","title":{"rendered":"TA Current and Temperature Control System"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\"><strong>Department:<\/strong>&nbsp;Physics<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Primary Investigator:<\/strong>&nbsp;Dr. Samir Bali<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Purpose:<\/strong>&nbsp;The cooling and trapping of atoms at microKelvin temperatures requires ultra-stable frequency-tunable diode laser systems, operating in single transverse and longitudinal mode with a linewidth &lt; 1MHz. However, these diode laser systems are limited in output power to typically less than 10 milliWatts. If the goal is to attain up to a few Watts of single-mode optical power suitable for state-of-the-art experimentation in laser cooling and atom trapping, one of the best methods currently available is to use a tapered amplifier (TA) chip, which is a semiconductor device that achieves high power while retaining the narrow linewidth and stability of the diode laser.<br><br>These tapered amplifier systems are available commercially in a price range of $14k &#8211; $47k per unit, depending on choice of center wavelength (650-110nm) and desired output power (0.15 &#8211; 2.5W). The IL built a state-of-the-art tapered amplifier systems, along with the driver circuits, at a cost of less than $5k per unit. The systems the IL built rival the commercial units in performance. Detailed plans for the design and construction of these systems are presented in &#8220;Design and construction of cost-effective tapered amplifier systems for laser cooling and trapping experiments&#8221;, J. Kangara, et al., American Journal of Physics, 82 (8), 805 &#8211; 817 (2014). This paper is one of 16 papers selected by the American Association of Physics Teachers (see&nbsp;<a href=\"http:\/\/www.aapt.org\/Resources\/Diodes.cfm\">http:\/\/www.aapt.org\/Resources\/Diodes.cfm<\/a>) to celebrate the 2014 Nobel in physics.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\" \/>\n\n\n\n<div class=\"wp-block-getwid-images-stack\"><div class=\"wp-block-getwid-images-stack__wrapper\"><div class=\"wp-block-getwid-images-stack__chunk\"><div class=\"wp-block-getwid-images-stack__media-wrapper\"><div class=\"wp-block-getwid-images-stack__media-inner-wrapper\"><img loading=\"lazy\" decoding=\"async\" width=\"1650\" height=\"1275\" class=\"wp-block-getwid-images-stack__media wp-image-439\" src=\"http:\/\/sites.miamioh.edu\/instrumentationlab\/files\/2023\/08\/WO64_BlockDiagramOfTALaserControl.jpg\" data-id=\"439\" data-link=\"https:\/\/sites.miamioh.edu\/instrumentationlab\/wo64_blockdiagramoftalasercontrol\/\" srcset=\"https:\/\/sites.miamioh.edu\/instrumentationlab\/files\/2023\/08\/WO64_BlockDiagramOfTALaserControl.jpg 1650w, https:\/\/sites.miamioh.edu\/instrumentationlab\/files\/2023\/08\/WO64_BlockDiagramOfTALaserControl-300x232.jpg 300w, https:\/\/sites.miamioh.edu\/instrumentationlab\/files\/2023\/08\/WO64_BlockDiagramOfTALaserControl-1024x791.jpg 1024w, https:\/\/sites.miamioh.edu\/instrumentationlab\/files\/2023\/08\/WO64_BlockDiagramOfTALaserControl-768x593.jpg 768w, https:\/\/sites.miamioh.edu\/instrumentationlab\/files\/2023\/08\/WO64_BlockDiagramOfTALaserControl-1536x1187.jpg 1536w\" sizes=\"auto, (max-width: 1650px) 100vw, 1650px\" \/><\/div><\/div><div class=\"wp-block-getwid-images-stack__media-wrapper\"><div class=\"wp-block-getwid-images-stack__media-inner-wrapper\"><img loading=\"lazy\" decoding=\"async\" width=\"1912\" height=\"2560\" class=\"wp-block-getwid-images-stack__media wp-image-440\" src=\"http:\/\/sites.miamioh.edu\/instrumentationlab\/files\/2023\/08\/InstrumentBlockBack-scaled.jpeg\" data-id=\"440\" data-link=\"https:\/\/sites.miamioh.edu\/instrumentationlab\/instrumentblockback\/\" srcset=\"https:\/\/sites.miamioh.edu\/instrumentationlab\/files\/2023\/08\/InstrumentBlockBack-scaled.jpeg 1912w, https:\/\/sites.miamioh.edu\/instrumentationlab\/files\/2023\/08\/InstrumentBlockBack-224x300.jpeg 224w, https:\/\/sites.miamioh.edu\/instrumentationlab\/files\/2023\/08\/InstrumentBlockBack-765x1024.jpeg 765w, https:\/\/sites.miamioh.edu\/instrumentationlab\/files\/2023\/08\/InstrumentBlockBack-768x1028.jpeg 768w, https:\/\/sites.miamioh.edu\/instrumentationlab\/files\/2023\/08\/InstrumentBlockBack-1147x1536.jpeg 1147w, https:\/\/sites.miamioh.edu\/instrumentationlab\/files\/2023\/08\/InstrumentBlockBack-1530x2048.jpeg 1530w\" sizes=\"auto, (max-width: 1912px) 100vw, 1912px\" \/><\/div><\/div><div class=\"wp-block-getwid-images-stack__media-wrapper\"><div class=\"wp-block-getwid-images-stack__media-inner-wrapper\"><img loading=\"lazy\" decoding=\"async\" width=\"1912\" height=\"2560\" class=\"wp-block-getwid-images-stack__media wp-image-441\" src=\"http:\/\/sites.miamioh.edu\/instrumentationlab\/files\/2023\/08\/InstrumentBlockFront-scaled.jpeg\" data-id=\"441\" data-link=\"https:\/\/sites.miamioh.edu\/instrumentationlab\/instrumentblockfront\/\" srcset=\"https:\/\/sites.miamioh.edu\/instrumentationlab\/files\/2023\/08\/InstrumentBlockFront-scaled.jpeg 1912w, https:\/\/sites.miamioh.edu\/instrumentationlab\/files\/2023\/08\/InstrumentBlockFront-224x300.jpeg 224w, https:\/\/sites.miamioh.edu\/instrumentationlab\/files\/2023\/08\/InstrumentBlockFront-765x1024.jpeg 765w, https:\/\/sites.miamioh.edu\/instrumentationlab\/files\/2023\/08\/InstrumentBlockFront-768x1028.jpeg 768w, https:\/\/sites.miamioh.edu\/instrumentationlab\/files\/2023\/08\/InstrumentBlockFront-1147x1536.jpeg 1147w, https:\/\/sites.miamioh.edu\/instrumentationlab\/files\/2023\/08\/InstrumentBlockFront-1530x2048.jpeg 1530w\" sizes=\"auto, (max-width: 1912px) 100vw, 1912px\" \/><\/div><\/div><\/div><div class=\"wp-block-getwid-images-stack__chunk\"><div class=\"wp-block-getwid-images-stack__media-wrapper\"><div class=\"wp-block-getwid-images-stack__media-inner-wrapper\"><img loading=\"lazy\" decoding=\"async\" width=\"2560\" height=\"1912\" class=\"wp-block-getwid-images-stack__media wp-image-442\" src=\"http:\/\/sites.miamioh.edu\/instrumentationlab\/files\/2023\/08\/TAControlFront-scaled.jpeg\" data-id=\"442\" data-link=\"https:\/\/sites.miamioh.edu\/instrumentationlab\/tacontrolfront\/\" srcset=\"https:\/\/sites.miamioh.edu\/instrumentationlab\/files\/2023\/08\/TAControlFront-scaled.jpeg 2560w, https:\/\/sites.miamioh.edu\/instrumentationlab\/files\/2023\/08\/TAControlFront-300x224.jpeg 300w, https:\/\/sites.miamioh.edu\/instrumentationlab\/files\/2023\/08\/TAControlFront-1024x765.jpeg 1024w, https:\/\/sites.miamioh.edu\/instrumentationlab\/files\/2023\/08\/TAControlFront-768x574.jpeg 768w, https:\/\/sites.miamioh.edu\/instrumentationlab\/files\/2023\/08\/TAControlFront-1536x1147.jpeg 1536w, https:\/\/sites.miamioh.edu\/instrumentationlab\/files\/2023\/08\/TAControlFront-2048x1530.jpeg 2048w\" sizes=\"auto, (max-width: 2560px) 100vw, 2560px\" \/><\/div><\/div><\/div><\/div><\/div>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\" \/>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>IL Comment:<\/strong>&nbsp;Researcher required a system that would monitor and control both the current and temperature of a TA (thermal amplifier) diode chip that they are using for their research experiments. Given the high cost of the TA (over $3K each), the electronics in this system need to be robust and reliable to run for extended periods of time.<br>&nbsp;<br>The design consists of a custom temperature and current control system. For the temperature control system, if the temperature deviates 1 \u00b0C above the set point, the current out the TA is taken to 0 Amps immediately (in the order of nanoseconds) to prevent damage to the TA. The output current is controlled via remote set point to a Thorlabs LD3000R current controller. The temperature output is controlled via remote set point to Wavelength Electronics temperature control board.<br>&nbsp;<br>The researcher is able to monitor the temperature set point, process value, and error between the two. Also, the current set point can be monitored as well.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Cost to researcher:<\/strong>&nbsp;$2382.09 (for 3 systems)<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Department:&nbsp;Physics Primary Investigator:&nbsp;Dr. Samir Bali Purpose:&nbsp;The cooling and trapping of atoms at microKelvin temperatures requires ultra-stable frequency-tunable diode laser systems, operating in single transverse and [&hellip;]<\/p>\n","protected":false},"author":6612,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_bbp_topic_count":0,"_bbp_reply_count":0,"_bbp_total_topic_count":0,"_bbp_total_reply_count":0,"_bbp_voice_count":0,"_bbp_anonymous_reply_count":0,"_bbp_topic_count_hidden":0,"_bbp_reply_count_hidden":0,"_bbp_total_topic_count_hidden":0,"_bbp_total_reply_count_hidden":0,"_bbp_forum_subforum_count":0,"footnotes":""},"class_list":["post-412","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/sites.miamioh.edu\/instrumentationlab\/wp-json\/wp\/v2\/pages\/412","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/sites.miamioh.edu\/instrumentationlab\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/sites.miamioh.edu\/instrumentationlab\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/sites.miamioh.edu\/instrumentationlab\/wp-json\/wp\/v2\/users\/6612"}],"replies":[{"embeddable":true,"href":"https:\/\/sites.miamioh.edu\/instrumentationlab\/wp-json\/wp\/v2\/comments?post=412"}],"version-history":[{"count":0,"href":"https:\/\/sites.miamioh.edu\/instrumentationlab\/wp-json\/wp\/v2\/pages\/412\/revisions"}],"wp:attachment":[{"href":"https:\/\/sites.miamioh.edu\/instrumentationlab\/wp-json\/wp\/v2\/media?parent=412"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}